PRODUCTS » Rotameters
|
 |
|
|
ACRYLIC BODY
ROTAMETERS |
|
 |
| |
|
|
|
 |
VEKSLER (ABR-191)
High Volume Acrylic Body Rotameters are useful for general
purpose application like water, air and inert gases.
The tapered metering tube is drilled in the solid block
and the scale is engraved on the body itself.
The other features are similar to the of the GTR-19 except
that it cannot be used for corrosive application and for
temperature above 60 Deg C.
Flow range is available from 100 to 40,000 LPH for water
and 0.5 to 450 m3/hr for air |
 |
|
| |
|
|
|
 |
 |
SPECIFICATIONS |
 |
| Flow
(Water) |
TOP / BOTTOM CONNECTION |
| Line
Size |
¼" |
½" |
¾" |
1" |
1½" |
2" |
2½" |
3" |
4" |
| 250
LPH |
* |
* |
- |
- |
- |
- |
- |
- |
- |
| 1000
LPH |
- |
* |
* |
- |
- |
- |
- |
- |
- |
| 2500
LPH |
- |
- |
* |
* |
- |
- |
- |
- |
- |
| 5000
LPH |
- |
- |
- |
* |
* |
- |
- |
- |
- |
| 8000
LPH |
- |
- |
- |
* |
* |
* |
- |
- |
- |
| 15000
LPH |
- |
- |
- |
- |
* |
* |
* |
* |
* |
| 20000
LPH |
- |
- |
- |
- |
- |
* |
* |
* |
* |
| 40000
LPH |
- |
- |
- |
- |
- |
* |
* |
* |
* |
|
 |
|
|
| |
 |
|
|
GLASS TUBE ROTAMETERS |
|
| |
Glass Tube Rotameters
consist of a tapered glass tube mounted vertically
in a frame with the small diameter at the bottom
and large end up. The tube contains a free moving
float that rests on the stopper at the base of the
tube. When the liquid flows, the float rises until
its weight is balanced by the up thrust of the fluid
and the float reaches a position of equilibrium.
At this position it indicates the instantaneous
rate of flow.
The flow rate can be read from the adjacent scale.The
pressure drop across the float is equal to its weight
divided by its maximum cross-sectional area in the
horizontal plane. Both in orifice type meter and
in the Rotameter, the pressure drop arises arises
from the conversion of pressure energy to kinetic
energy and from the frictional losses. Thus Rotameter
may be considered as an orifice meter with a variable
aperture and the formula derived for the orifice
meter is applicable here with only minor changes |
|
| |
 |
 |
DESIGN FEATURES |
|
| |
- Accuracy +/ -2% of full scale
- Overall length of 500 mm in flanged versions
- End connections can be rotated through 360 Deg
- Connection orientation
- Top & Bottom, rear, bottom and rear, rear and
top
- Tube can be changed without disconnecting the meter
from the line
- Detachable scale with flow in customers engineering
units
- Standard interchangeable floats for a given size
- Adjustable packing gland
- Wide choice of flow ranges for individual requirement
- Sturdy metallic construction to with stand pipeline
stress and vibration
- 1/2" to 4" Line size and max flow upto
30000 LPH for online installation
- Optional high and low alarms
|
 |
 |
MATERIAL
OF CONSTRUCTION |
| |
- Borosilicate Glass Tube
- SS 304/SS 316/Teflon Floats
- CC, MS, SS 304, SS 316, Rubber lined PTFE lined
End Fittings, threaded or Flanged (ASA 150 #, BS 10
Table D/E or as per customer's requirement)
- Neoprene/ Teflon/ Silicon/ Viton Packing
- MS/ CS Powder coated Frame as standard and SS optional
- Aluminium frame with safety glass/ acrylic window
- CS/SS 304/SS 316 bolts
- Cast Steel epoxy painted gland housing
|
 |
|
|
| |
 |
|
|
METAL TUBE ROTAMETERS |
|
| |
| Metal Tube Rotameters
are available for use in harsher duties in liquids
and gases where glass tubes are not allowed for
safety reasons. These are very rugged and robust
yet inexpensive for flow rate indication purposes.
MTR can be used for opaque and turbid fluids at
high operating temperature and pressures.The Flow
is indicated by a pointer, which is magnetically
coupled with the float that rises in a tapered tube
with increase in flow. |
|
| |
 |
 |
DESIGN FEATURES |
|
| |
- SS/ Teflon lined body
- Die-cast Aluminum housing with Aluminium
pointer and SS 304 hardware
- High Pressure and Temperature service
- Linear flow reading and output signals
- Easy to read local display
- Line size from 1/2" to 4"
- Flow 100 to 70000 LPH for water and 2000
m3/hr for air
- Flanged connections to any standard ASA,
BST, DIN etc.
- Optional alarms and 4-20 mA output
|
|
 |
|
|
| |
 |
|
|
BYE PASS ROTAMETERS |
|
| |
|
|
| |
VEKSLER Bye Pass Rotameters
are available for line sizes 2" and above. The complete
assembly consists of an Orifice plate, Flanges of the
main pipe line, by-pass piping with isolation valve and
fittings, range orifice and the Rotameter. The Orifice
calculations and design is bases on IS or BS standard.
By-Pass Rotameters are the most economical solution for
flow measurement in large pipe lines and for large rate
of flow but the use is limited to solid particles and
slurries that tend to clog the range orifice and may result
in malfunctioning. |
|
| |
|
 |
 |
DESIGN FEATURES |
| |
- SS304/ SS316 Orifice plate
- CS/Forged and SS Flanges
- Accuracy +/-2% of full flow
- Also available without main line flanges
- Optional alarms and 4-20 mA output
|
|
|
|
|
 |